DIGITAL CONDUCTIVITY
Click to Enlarge

Digital Conductivity

(HL-8052 )
  • Highly Stable and Accurate
  • Cell Constant Adjustment Facility
  • Available in Lab & Field models
  • Temperature Coefficient Correction facility
  •  
    Model Conductivity
    HLSI- 19160
    Table Model
    Conductivity
    HLSI-19161
    Portable Model
    Display 3 1/2 Digit LED 3 1/2 Digit LCD
    Range 5 Ranges
    0 - 1000 Mohs/cm
    2 Ranges
    2 & 20 Mohs/cm
    Temperature Compensation Manual 0-50oC -
    Cell Constrant Adjustment Adjustable Pre Adjustable
    Conductivity Cell Platinum DIP Platinum DIP
    Measuring Frequency 1000 Hz 1000 Hz
    Accuracy +1% FSI +1% FSI
    Power 230v + 10% 1 x 9V Battery
    Dimensions 76 x 275 x 175 mm 85 x 28 x 165 mm
    Weight 2 kg. (Approx.) 0.8 kg. (Approx.)
    Accessories Conductivity Cell,Operation Manual, Dust Cover

    More detailQuantity :



    POTENTIOMETERS
    Click to Enlarge

    Potentiometers

    (HL-8053 )
    HLSI- 19164
    Range
    0 to+ 1999.9mV
    Resolution 1 mV
    Repeatability + 1 mV
    Accuracy + 1 mV +digit
    Input Impedancy 10 ohms
    Operating Temperature 10 to 50oC
    Display 3 1/2 Digit 0.5 seven segment LED display Indication
    Power 230V + 10?, 50Hz
    Dimensions 76 x 275 x 170 mm.
    Weight 2 Kg (approx.)
    Standard Accessories
    Electrode 2 Nos.
    Dust Cover 1 No.
    Electrode Stand 1 No.
    Manual 1 No

    More detailQuantity :



    DIGITAL D.O.METER
    Click to Enlarge

    Digital D.o.meter

    (HL-8054 )
    Model- HLSI 19165
    Oxygen Dissolved in water, often referred to as DO is a very important parameter of water quality and is an index of physical and biological processes going on in water.
      
    There are two main sources of dissolved oxygen in water (i) Diffusion of Oxygen from air to water is a physical phenomenon and depends upon solubility of oxygen which, in turn, is influenced by factors like temperature, water movements and salinity etc. Photosynthetic activity is a biological phenomenon carried out by autotrophs (mainly phytoplankton) in water and depends upon autotroph population, light conditions and available gases etc.
      
    Range D.O. 0 to 20.0 ppm
    Resolution D.O. 0.1 ppm
    Accuracy D.O. 0.1 ppm + 1 count
    Temp. Compensation 0o C to 50o C Manual
    Compensation D.O. + 3%
    D.O. Sensor type D.O. Amperometric Gold/Silver membrane
    General  
    Display 3 1/2 digit LED display
    Power 230V A.C. 50 Hz
    Weight 2 Kg
    Standard Accessories  
    DO Electrode 1 Nos.
    Instruction Manual 1 Nos.
    D.O. Membranes 10 Nos.

    More detailQuantity :



    DIGTAL TDS METERS
    Click to Enlarge

    Digtal Tds Meters

    ( )
  • Highly Stable and Accurate
  • Cell Constant Adjustment Facility
  • Available in Lab & Field models
  • Temperature Coefficient Correction facility
  •  
    Model HLSI-19167 TDS
    Table Model
    HLSI-19168 TDS
    Portable Model
    Display 3 1/2 Digit LED 3 1/2 Digit LED
    Range 5 Ranges
    0-1000 ppt
    Mohs/cm
    2 Ranges
    0-2000 ppm
    0-20 ppt
    Temperature Compensation Manual 0-50oC -
    Cell Constrant Adjustment Adjustable Pre Adjustable
    Conductivity Cell Platinum DIP Platinum DIP
    Measuring Frequency 1000 Hz 1000 Hz
    Accuracy +1% FSI +1% FSI
    Power 230v + 10% 1 x 9V Battery
    Dimensions 76 x 275 x 175 mm 85 x 28 x 165 mm
    Weight 2 kg. (Approx.) 0.8 kg. (Approx.)
    Accessories TDS Cell,Operation Manual, Dust Cover

    More detailQuantity :



    FLAMEPHOTO METERS
    Click to Enlarge

    Flamephoto Meters

    (HL-8057 )
  • Simple & Easy to Operate
  • Narrow Band Interference Filters
  • Dual Channel Display
  • Na & K at Single Aspiration
  •  
    Model HLSI-19172 HLSI-19173
    FLAME PHOTOMETER UNIT
    No. of Filters Na & K (Ca & Li optional) Na & K (Ca & Li optional)
    Range Na: 0-100 ppm Ca: 20-100 ppm
    K : 0-100 ppm Li: 10-100 ppm
    Na: 0-200 meq/l Ca: 0-2 meq/l
    K : 0-100 meq/l Li: 0-10 meq/l
    Sensitvity Na: 5 ppm Ca: 10 ppm
    K : 5 ppm Li: 10 ppm
    Na: 5 pmm Ca: 10 ppm
    K : 5 pmm Li: 10 ppm
    Display 2 1/2 digit bright LED Display Dual 2 1/2 digit bright LED Display
    Accuracy + 2% upto 40 ppm
    + 5% above 40 ppm
    + 2% upto 100 meq/l
    + 5% above 100 meq/l
    Repeatability + 2 Count + 2 Count
    Detector Silicon Photodiode Silicon Photodiode
    Filters Narrow band interference glass filters Narrow band interference glass filters
    Nebulizer Black bakelite, axial flow type Black bakelite, axial flow type
    Flame System LPG and dry oil free air LPG and dry oil free air
    Warmup time 10 minutes 10 minutes
    Power 230V + 10% AC 50 Hz 230V + 10% AC 50 Hz
    Size (LxBxH) 355 x 250 x 210 mm 455 x 250 x 210 mm
    Weight 6.5 kg (Approx.) 7.5 kg (Approx.)
     
    COMPRESSOR UNIT
    Air Supply By Oil free mini compressor unit with pressure regular
    Combustion LPG controlled by precision regulator
    Power 230V +10% AC 50 Hz
    Size (LxBxH) 275 x 192 x 240 mm
    Weight 9 Kg (Approx.)
    Accessories Instrument with Na & K Filters, Instruction Manual, Dustcover, Chimney, Air Tubing

    More detailQuantity :



    DIGITAL TURBIDITY METERS
    Click to Enlarge

    Digital Turbidity Meters

    (HL-8056 )
    Model HLSI-19170 HLSI-19171
    Range 0 to 200 JTU
    0 to 1000 JTU
    2 Ranges
    0 to 20.00 NTU
    0 to 200.00 NTU
    2 Ranges
    Resolution 1 JTU 0.1, 1 NTU
    Accuracy +3% FS + 1 digit +2% FS + 1 digit
    Sample System 30 mm clear glass tube 30 mm clear glass tube
    Light Source 6.8 V, Tungsten Lamp 6.8 V, Tungsten Lamp
    Detector Photodiode Photodiode
    Display 3 1/2 digit LED display 3 1/2 digit LED display
    Power 220V+ 10% AC 50 Hz 220V+ 10% AC 50 Hz
    Size (LxBxH) 305 x 305 x 165 mm 305 x 305 x 165 mm
    Weight 4 kg (approx.) 4 kg (approx.)
    Accessories Test Tube Set, Operation Manual & Dustcover
    Other Models Analog Nephelometer Battery cum Mains Operated also Available

    More detailQuantity :



    KARL FISHER TITRIMETERS
    Click to Enlarge

    Karl Fisher Titrimeters

    (HL-8058 )
  • Auto Titration Control
  • Auto Zero Burette
  • Adjustable Timer
  • Visual & Audible Alarm
  •  
    Model HLSI-19175 HLSI-19176
    Display Array of 10 LED's in line Analog Ammeter
    Sample Size 1 - 50 mg of water 1 - 50 mg of water
    K.F.Dispensing Resolution 0.05 ml. 0.05 ml.
    Indication RUN ADD END
    Display in Auto Mode
    RUN ADD END
    Display in Auto Mode
    Detection Current Sensing by Electronic control Current Sensing by Electronic control
    K.F.Flow Highly sensitive solenoid control
    Volve for automatic control of K.F.Reagent
    Highly sensitive solenoid control
    Volve for automatic control of K.F.Reagent
    Measuring Electrode Duel Platinum Electrode Duel Platinum Electrode
    Titration Cell Air tight 200 ml. Glass vessel Air tight 200 ml. Glass vessel
    End Point Delay 30 seconds 30 seconds
    Buzzer Yes -
    Timer Ajustable Timer Fixed Timer
    Stirrer Variable speed magnetic stirrer
    With On/Off control
    Variable speed magnetic stirrer
    With On/Off control
    Burette Pressure filling auto zero burette
    With 0.05 ml. Resolution
    Pressure filling auto zero burette
    With 0.05 ml. Resolution
    Power 230V + 10% AC 50Hz 230V + 10% AC 50Hz
    Size 435 x 305 x 150 mm 435 x 305 x 150 mm
    Weight 5 kg. (Approx.) 5 kg. (Approx.)
    Accessories Burette(Clear Glass) 10 ml., Reservoir Bottle 500 ml., Rubber Bellow for Pumping Air, Titration Cell 200 ml, Dual Platinum Electrode, Teflon Coated Magnetic Stirring Capsule, Nozzle, Moisture Trap with Rubber Tubing, Instruction Manual

    More detailQuantity :



    DIGITAL SPECTROPHOTOMETER
    Click to Enlarge

    Digital Spectrophotometer

    (HL-8059 )
  • Range 340 to 960 nm
  • Direct Concentration Facility
  • Latest Solid State IC Technology
  • Digital Display
  • Highly Stable and Accurate
  •  
    Model HLSI-19180 HLSI-19181
    Range 340 to 960 nm 340 to 960 nm
    Resolution 0.1%T, 0.001 Abs 0.1%T, 0.001 Abs
    Output %T: 0 t0 100%, Abs; 0 to 1.999, Conc; 0 to 1999 %T: 0 t0 100%, Abs; 0 to 1.999, Conc; 0 to 1999
    Detector Silicon Photodiode Silicon Photodiode
    Light Source 6V, 1 Amp. Vertical Tungsten Halogen Lamp 6V, 1 Amp. Vertical Tungsten Halogen Lamp
    Monochromater 600 Lines / mm grating 600 Lines / mm grating
    Path Length 10 mm 10 mm
    Spectral Bandwidth 10 mm 10 mm
    Wave Length Resolution 5 nm 1 nm
    Wave Length Accuracy 2.5 nm 1 nm
    Repeatability +2 nm +1 nm
    Display 3 1/2 digit LED Display 3 1/2 digit LED Dual Display
    Opeating Temp. 5 to 45oC 5 to 45oC
    Power 230V+ 10% AC 50 Hz 230V+ 10% AC 50 Hz
    Dimensions 490 x 300 x 165 mm 490 x 300 x 165 mm
    Weight 8.5 kg (approx.) 8.5 kg (approx.)
    Accessories Test Tubes(12mm dia) 10 nos

    More detailQuantity :



    MICROPROCESSOR SPECTROPHOTOMETER
    Click to Enlarge

    Microprocessor Spectrophotometer

    (HL-8060 )
    A versatile, Rugged, Easy to operate and Accurate Instrument to determine Absorbance, % Transmission and Concentration of Liquids

    More detailQuantity :



    MICROPROCESSOR UV-VIS SPECTROPHOTOMETER
    Click to Enlarge

    Microprocessor Uv-vis Spectrophotometer

    (HL-8061 )
  • Cover 195 to 1000nm
  • 4 Position Cuvette Holder
  • RS-232C Computer Interface
  • High wavelength Precision
  • Compact & Good Looking Shape
  • Highly Accurate & Stable
  •  
    Model HLSI - 19185
    Photometric Range % T:0 to 100%, Abs.:0 to 1.999
    Conc.:0 to 1999, K-Factor:0 to 1999
    Accuracy +0.005 Abs at 1.0 Abs
    +0.010 Abs at 1.0 Abs
    Stray Light Less thn 0.1% Abs at 320 nm
    Readability + 1 Count
    Data Readout Single Line LCD display
    Key Board 4 Keys, Soft touch membrane type
    Painter Interface Printer interface for any printer
    Serial Interface RS 232C interface
    Light Source a) Tungsten Halogen Lamp
    b) Deuterium Lamp (D2)
    Detector Wide range Silicon Photodiode
    Optics Complete mirror optics with resolution 1200 grooves/mm grating
    Sample Holder 4 position adjustable sample holder
    Power 230V + 10%, 50 Hz. AC
    Dimensions 420 x 350 x 240 mm (lxbxh) Approx.
    Weight 10 Kg (Approx.)
    Technical Specifications  
    Wavelength 195 to 1000nm
    Spectral Bandwidth 2 nm
    Accuracy + 0.5 nm
    Repeatability + 0.3 nm
    Resolution 0.1 nm

    More detailQuantity :



    WATER & SOIL ANALYSIS KIT
    Click to Enlarge

    Water & Soil Analysis Kit

    (HL-8063 )
  • 3 1/2 digit LCD Display
  • Mains cum Battery operated
  • Measures pH, mV, Conductivity
  • TDS, DO, Temperature & Turbidity
  • Housed in VIP Briefcase
  •  
    Model   HLSI-19195 HLSI-19196 HLSI-19197
    pH Range 0 to 14pH 0 to 14pH 0 to 14pH
    Temp. Comp. 0oC (Manual) 0oC (Manual) 0oC (Manual)
    Resolution 0.01pH 0.01pH 0.01pH
    Accuracy +0.01 pH +0.01 pH +0.01 pH
    O.R.P./mV Range N.A. 0 to + 1999 mV 0 to + 1999 mV
    Resolution 0.01pH N.A. 1 mV
    Accuracy N.A. + 1 mV + 1 digit + 1 mV + 1 digit
    Conductivity Range 1 5 5
    Cell Constant 0.4 - 1.5 Adj 0.4 - 1.5 Adj 0.4 - 1.5 Adj
    Resolution 0.1 Micro mhos 0.1 Micro mhos 0.1 Micro mhos
    Accuracy + 0.5% FS + 0.5% FS + 0.5% FS
    Temperature Range 0o - 100oC 0o - 100oC 0o - 100oC
    Resolution 0.1oC 0.1oC 0.1oC
    Accuracy +0.1oC + digit +0.1oC + digit +0.1oC + digit
    T.D.S. Range 1 5 5
    Cell Constant 0.4 - 1.5 Adj 0.4 - 1.5 Adj 0.4 - 1.5 Adj
    Resolution 0.1ppm 0.1ppm 0.1ppm
    Accuracy +5% FSD +5% FSD +5% FSD
    D.O. Range 0-20 ppm 0-20 ppm N.A.
    Temp. Comp. 0.1 ppm 0.1 ppm N.A.
    Resolution +0.3 ppm +0.3 ppm N.A.
    Accuracy 5o to 50o (Manual) 5o to 50o (Manual) N.A.
    Turbidity Range 0-1000 NTU/JTU N.A. N.A.
    Resolution 1 NTU/JTU N.A. N.A.
    Display Selenium Photocell 3 1/2 digit LCD display
    Power Suppy 6.8v, 300mA 1.5V x 6 Dry Cells or 230V + 10% 50 Hz
    Accessories 230v + 10% and In-built Battery pH Combination Electrode, Conductivity / TDS Cell, DO Probe, Temp Probe, Standard Solution, D.O. Memberanes, Cell Container & Instruction Manual

    More detailQuantity :



    MICROPROCESSOR UV-VIS SPECTROPHOTOMETER(Double Beam)
    Click to Enlarge

    Microprocessor Uv-vis Spectrophotometer(double Beam)

    (HL-8062 )
    Model - HLSI-19190
     
    Salient Features
  • Wide wavelength range, satisfying requirements of various fields
  • Fully automated design, realizing the simplest measurement & satisfying the requirements of pharmacopoeia.
  • Maximum of 9 wavelenths & 7 samples scan be measured at one time.
  • Automatic change-over between W lamp & D 2 lamp
  • Optimized optics and large scale integrated circuits design, light source and receiver from world famous measurement all add up to high performance and reliability
  • Rich measurement methods:wavelength scan, time scan, multi-wavelenth determination, multi-order derivative determination, double-wavelength method and triple-wavelength method etc., meet different measurement requirement.
  • Automatic 10mm 8-cell holder
  • Data output can be obtained via a printer port and a RS-232 interface
  • Parameters and data can be saved for user's convenience
  • PC controlled measurement can be achieved for more accurate and flexible requirement
  •  
    Technical Specifications
    Wavelength Range 190-1100 nm
    Spectral Bandwidth 1 nm
    Working Mode T, A, C, E
    Optical System Double beam
    Scanning Speed Fast / Medium / Slow
    Photometric Range -0.3 - 3.5 A, 0 to 220 %T
    Wavelength Accuracy +0.3 nm
    Wavelength Reproducibility < 0.10 nm
    Photometric Accuracy + 0.3% T (0-100% T)
    +0.002 A (0-0.1 A)
    Photometric Reproducibility < 0.15 % T
    Stray Light < 0.1% T (Nal. 220nm, NaNO2 340 nm)
    Baseline Flatness + 0.002 A
    Stability < 0.001A/h (at 500 nm, after warming up)
    Noise +0.001A (at 500 nm, after warming up)
    Detector Dual Silicon Photodiode
    Display 6 inches high light blue LCD
    Power AC:220V + 10%, 50 Hz.
    Dimensions 630 x 470 x 210 mm
    Weight 26 Kg
     
    Accessories
    Glass Cells 16 No.
    Quartz Cells 4 Nos.
    Fuse 3 Nos.
    Instrument Cover 1 No.
    Software CD 1 No.
    RS 232 Cable 1 No.
    Operation Manual 1 No.

    More detailQuantity :



    DIGITAL COLONY COUNTERS
    Click to Enlarge

    Digital Colony Counters

    (HL-8064 )
  • 110mm Dia Magnifying Glass
  • Audible Confirmation of each Count
  • Uniform Readout from 0.9999
  • Auto Marker Pen
  • Wolffhuegel Glass Grid with Focusing Facility
  •  
    Model HLSI-19200
     
    Specifications
    Digital Display 4 digit, 999 Max. Count(Model :LT-37)
    3 digit, 999 Max. Count(Model:LT-36)
    Dish Size 110 mm
    Magnification x 1.7
    Dimensions L 274 x B 320 x H 167 mm (approx.)
    Weight 3 kgs. (approx.)
    Packaging 23 cm x 28 cm x 20 cm
    Power 230V - 10% AC, 50 Hz, 40W
    Accessories Marking Pen (1 No.), Magnifier Lens (1 No.)

    More detailQuantity :



    DIGITAL AUTOMATIC MELTING POINT APPARATUS
    Click to Enlarge

    Digital Automatic Melting Point Apparatus

    (HL-8065 )
    Model HLSI - 19201
     
  • Fully Automatic
  • Latest Technology
  • Range upto 350oC
  • Highly Accurate
  • No Silicon Oil/ Heating Media Required
  •  
    Specifications
    Display Digital 3 1/2 Digit, Bright LED
    Accuracy 1%
    Operation Fully Automatic
    Dimensions L 405 x B 360 x H 235 mm (approx)
    Weight 5 Kg (approx.)
    Power 230V + 10?, 50Hz
    Accessories Capillary Tube - 100 No.
    Cleaning Tool - 1 No.

    More detailQuantity :



    ELECTRICAL CONDUCTIVITY METER (Microprocessor based)
    Click to Enlarge

    Electrical Conductivity Meter (microprocessor Based)

    (HL-8066 )
  • Auto Calibration
  • Storage of 100 samples
  • Printer attachment facility
  • Soft touch membrane keys
  •  
    Model HLSI-19202
     
    Specifications
    Display 16 x 2 alpha numeric LCD display
    Range 0.1 uS to 100mS (6 decadic ranges)
    Resolution 0.1
    Accuracy + 1% of F.S. + 1 digit
    Calibration Auto / Manual
    Temperature Range 0 to 100oC
    Cell Conatant 0.1 to 5.0
    Storage Upto 100 samples
    Power 230V + 50Hz
    Accessories Conductivity Cell, Temperature probe, Stand, Clamp, Dust cover, Manual